Motor Stroke Calibration Packet

The device reports a data packet after a motor stroke calibration.

Packet description:
Item Byte Command Description
Calibration Result 1+1 05 00=Not calibrated, 01=Success, 02=Over-range, 03=Temperature control disable, 04=Uninstall
Total Motor Stroke 1+2 02 UINT16
Motor Position 1+2 03 UINT16
Example:
  1. Calibration success
    0501024009
    Command Value
    05 01=Success
    02 Total motor stroke: 40 09=> 09 40=2368
  2. Calibration failure
    0502
    Command Value
    05 02=Over-range