VS133-P Quick Start Guide
Overview
Installation Video
Packing List
![]() |
![]() |
![]() |
| 1 × VS133-P Device | 4 × Wall Mounting Sets | 8 × Staff Tags |
![]() |
![]() |
![]() |
| 1 × Multi-interface Cable | 1 × PoE Injector (Optional) | 1 × Quick Guide Card |
![]() |
||
| 1 × Warranty Card |
The device is also compatible with multiple mounting kits and accessories that can be purchased independently. For detailed information about them, refer to Accessories for Milesight People Counters.
Hardware Introduction
Main Components
The following figure shows the main components of the device.

| Name | Description |
|---|---|
| RGB LED Indicator | Provides visual status indications through LED Indicator. |
| Reset Button | Button for resetting the device. |
| ToF Sensor | Uses depth data instead of video for privacy-safe people detection. |
| Ethernet Port (PoE) | Provides power, data communication and multi-device stitching capability. |
| Multi-interface | Equips with Digital Input/Output and RS485 interfaces (Under development). For wiring details, refer to Wiring Diagram. |
Button and LED Indicators
The device has a button and an LED indicator for resetting functions. For the functions of the button and the corresponding LED indicator status, refer to the following table.
| Function | Action | LED Indicator |
|---|---|---|
| Reset to Factory Default | Press and hold the reset button for more than 10 seconds. | Green light blinks until the reset process is completed. |
Wiring Diagram
This following figure shows the wiring diagram.

- DI: By default, two connected contacts = low level, two disconnected contacts = high level.
- DO: Loads up to 1A@24V DC.
Dimensions
The following figure shows the device dimensions (unit: mm).

Power Supply
The Ethernet port can receive power by connecting to an 802.3af standard PoE switch or PoE injector.


Installation Prerequisites
Choose an Installation Position
- Avoid installing the device against the wall. Keep the
following minimum distances between the device and the wall:

Condition Standard Environment Dark Carpet/Floor (need to set noise filtering to the maximum level) Normal imaging x > 50 cm, y > 60 cm x > 50 cm, y > 75 cm Normal counting x > 50 cm, y > 50 cm x > 50 cm, y > 50 cm - When installing above a swinging door, keep the door normally open. If the door
must stay closed, install the device on the opposite side, at least 30 cm
away from the door's movement path.

- Keep the ToF sensor facing downward and avoid tilted installation.
- Ensure no objects block the ToF light within a 30 cm radius in front of the device.
- Avoid direct Infrared LED light in the detection area.
- Do not install the device close to glass or mirror surfaces.
Check Environment Conditions
- Avoid 940 nm light sources, which may cause incorrect counting.
- Direct outdoor sunlight on the monitoring area has no effect. However, avoid mirrored reflections that direct sunlight onto the ToF sensor.
- Keep the live view free of obstacles. Obstacles may cause the device imaging to
appear abnormally red and affect counting accuracy. Adjust the noise filtering
level according to the actual image: the harder it is to distinguish targets,
the higher the filter value should be.

Estimate Detection Coverage
The monitored area is the full range visible to the device (shown on the dashboard). The detection area is the smaller region within it where the device can actually detect changes in the number of people. The detection area depends on the device's field of view angle, installation height, and target height.
| Parameter | Description | Value |
|---|---|---|
| Δd | Distance measurement error | 0.035 m |
| hmax | Maximum pedestrian height | Example: 1.8 m |
| h | Average pedestrian height | Example: 1.7 m |
| H | Installation height | hmax+d+Δd ≤ H ≤ 3.5 m |
| α | ToF horizontal field of view angle | 98° |
| β | ToF vertical field of view angle | 80° |
| x | Detection range length | 2 × tan(α/2) × (H−h) |
| y | Detection range width | 2 × tan(β/2) × (H−h) |
Installation height limits: Maximum=3.5m. Minimum = hmax + d + Δd.
For example, with hmax = 1.8 m: 1.8 + 0.5 + 0.035 = 2.335 m.
Conclusion: 2.335 m ≤ H ≤ 3.5mThe following illustration uses an installation height of 3 m and a target height of 1.7 m as an example:

| Installation Height (m) | Monitored Area (m2) | Detection Area (m2) |
|---|---|---|
| 2.5 | 5.75 × 4.20 | 1.84 × 1.34 |
| 2.6 | 5.98 × 4.36 | 2.07 × 1.51 |
| 2.7 | 6.21 × 4.53 | 2.30 × 1.68 |
| 2.8 | 6.44 × 4.70 | 2.53 × 1.85 |
| 2.9 | 6.67 × 4.87 | 2.76 × 2.01 |
| 3.0 | 6.90 × 5.03 | 2.99 × 2.18 |
| 3.1 | 7.13 × 5.20 | 3.22 × 2.35 |
| 3.2 | 7.36 × 5.37 | 3.45 × 2.52 |
| 3.3 | 7.59 × 5.54 | 3.68 × 2.69 |
| 3.4 | 7.82 × 5.71 | 3.91 × 2.85 |
| 3.5 | 8.05 × 5.87 | 4.14 × 3.02 |
Plan Multi-Device Coverage
When the area you need to monitor exceeds a single device's detection range, use multiple devices side by side to extend coverage. The devices stitch their detection ranges together to act as one unified monitoring zone. Use the following parameters to calculate how many devices are required for your space.
| Parameter | Description | Value |
|---|---|---|
| Δd | Distance measurement error | 0.035 m |
| hmax | Maximum pedestrian height | Example: 1.8 m |
| h | Average pedestrian height | Example: 1.7 m |
| H | Installation height | hmax+d+Δd ≤ H ≤ 3.5 m |
| α | ToF horizontal field of view angle | 98° |
| β | ToF vertical field of view angle | 80° |
| x | Detection range length of each device | x = 2 × tan(α/2) × (H−h) |
| y | Detection range width of each device | y = 2 × tan(β/2) × (H−h) |
| a | Number of devices required along the coverage length | Coverage length ÷ x, round to the nearest integer based on deployment requirements |
| b | Number of devices required along the coverage width | Coverage width ÷ y, round to the nearest integer based on deployment requirements |
Example: For a coverage area of 6 m × 3 m (length × width) with VS133-P devices installed at 3 m height (H) and 1.7 m target height (h):
x = 2.99 m, a = Coverage length ÷ x = 6 ÷ 2.99 ≈ 2.00≈ 2 devices
y = 2.18 m, b = Coverage width ÷ y = 3 ÷ 2.18 ≈ 1.38≈ 2 devices
Conclusion: 2 × 2 = 4 devices are required for complete coverage of the 6 m × 3 m area.
Install the Device
- Review the Installation Prerequisites and confirmed that your site meets the position, environment, and coverage requirements.
- Verify that the device and accessories are complete according to the Packing List.
- Tools: electric drill (6 mm drill bit), marker pen, screwdriver.
- Flat ceiling, thickness > 30 mm.
- No tilted installation. The device must be parallel to the ground.
- Remove the cover from the device.

- Fix wall plugs into ceiling holes.
- Mark the drilling positions on the ceiling according to the mounting holes of the device.
- Drill four 6 mm holes at the marked positions.
- (Optional) If wires need to enter the ceiling interior, drill an additional wire hole of suitable size.
- Insert the wall plugs into the drilled ceiling
holes.

- Route and Connect the Cables.
- Remove the rubber plugs from the rubber sleeve.
- Route all required cables through the openings in the rubber sleeve and connect them as needed.
- (Optional) If the alarm I/O function is needed, connect a
multi-interface cable to the device.

- If the wires need to protrude from the side, pass them through the side block instead.
- Secure the device with mounting screws into the wall plugs.
Adjust the mounting direction to match your detection area requirements.

- Fix the cover back onto the device.

- Log in to the web GUI and check the preview on the Dashboard page to verify the installation is correct.
Access the Device
The device can be configured through the web GUI accessible over Ethernet port. The recommended browsers are Chrome and Microsoft Edge.
The default IP address of the device is 192.168.5.220 (can be found on
the device label).
Preparations: Computer and network cable
- Use the network cable to connect the device and the computer.
- Click Start → Control Panel →
Network and Internet → Network and Sharing
Center.

- Click Ethernet → Properties and double
click Internet Protocol Version 4 (TCP/IPv4). The
Internet Protocol Version 4 (TCP/IPv4) Properties
dialog box is displayed.

In the Use the following IP address area, perform the following operations:- Enter an IP address (such as
192.168.5.61) that is in the same subnet as the device.Note: This IP address must be unique and not used by any other device on the network. - Set Subnet mask to
255.255.255.0. - Set Default gateway to
192.168.5.220. - Click OK.
- Enter an IP address (such as
- Open a browser and enter Ethernet IP address
192.168.5.220. - The Activation dialog box is displayed. Set the login
password that is 8 to 63 characters long and contains numbers, lowercase
letters, uppercase letters, and special characters, then click
. 
- The Set Security Questions dialog box is displayed. Set the
three security questions when using the device for the first time and click
. 
- The following page is displayed. Log in with username (admin) and
custom password.
Note: The account will be locked for 10 minutes after five failed login attempts. It is recommended to regularly update the password to enhance device security. - (Optional) You can click Forget Password? in the login page to reset the password by answering three security questions when you forget the password if you set the security questions in advance.
FCC Statement
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and.
(2) This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Related Resource
For more information, please refer to Milesight Document Center.