Installation
- Installation location
-
- In order to provide the best data transmission, please ensure the device is deployed within the signal range of the LoRaWAN® gateway and keep it away from metal objects and obstacles.
- The device must be placed in a horizontal position above the detected object so that it has a clear path to the object. The ultrasonic sensor delivers optimal measurement performance when installed perpendicular to the detected object.
- The device should be installed at least 30cm away from the side-wall without obstructions blocking the ultrasonic signal If the device needs to be installed on the side wall, please ensure the ultrasonic horn is away from the side wall.
- Do not install the ultrasonic sensor above the influent stream to ensure the measured surface rather than the incoming stream.
- The device is not suitable for snow level detection. Please contact us to order a customized version if needed.
- The measurement accuracy of the device may be affected by environmental factors at the installation location, such as solar radiation and water surface fluctuations.
- Installation Steps
- Step 1:Drill two holes on the container cover according to the location
of device mounting holes.