Uplink Data

This chapter describes the reported data of the device.

Basic Information

The device will report a basic information packet whenever joining the network.
Item Channel Type Byte Description
Power On ff 0b 1 Device is on
Protocol Version ff 01 1 Example: 01=V1
Hardware Version ff 09 2 Example: 03 10 = V3.1
Software Version ff 0a 2 Example: 03 01 = V3.1
Serial Number ff 16 8 16 digits
Overcurrent Alarm ff 24 2

Byte 1: 00-disabled, 01-enabled

Byte 2: current threshold, unit: A

Button Lock

ff 25 2

0000-disabled, 0080-enabled

Power Consumption

ff 26 1 00-disabled, 01-enabled
Overcurrent Protection ff 30 2

Byte 1: 00-disabled, 01-enabled

Byte 2: current threshold, unit: A

Example:
ff0bff ff0101ff166762d21130962038 ff090100 ff0a0108 ff240000 ff30010a ff250000 ff2601
Channel Type Value
ff 0b ff
ff 01 Protocol Version: 01=V1
ff 16 SN: 6762d21130962038
ff 09 Hardware Version: 0100=V1.0
ff 0a Software Version: 0108=V1.8
ff 24 Overcurrent Alarm: 00=disable, 00=0A
ff 30 Overcurrent Protection:01=enable, 0a=10A
ff 25 Button Lock: 00 00=disable
ff 26 Power Consumption: 01=enable

Periodic Report

Item Channel Type Byte Description
Voltage 03 74 2 UINT16/10, Unit: V
Active Power 04 80 4 UINT32, Unit: W
Note: When the device is powered off, this parameter will be 0.
Power Factor 05 81 1 UINT8, Unit: %
Power Consumption 06 83 4 UINT32, Unit: Wh
Total Current 07 c9 2 UINT16, Unit: mA
Socket Status 08 70 1 00: Close, 01: Open
Example:
Report data according to reporting interval (20mins by default).
087001 058164 07c90200 0374b208 068301000000 048001000000
Channel Type Value
08 70 Socket status: 01 = Open
05 81 Power Factor: 64=> 100%
07 c9 Current: 02 00=>00 02=2mA
03 74 Voltage: b2 08=>08 b2=2226/10=222.6V
06 83 Power Consumption: 01 00 00 00=>00 00 00 01=1 Wh=0.001 kWh
04 80 Active Power: 01 00 00 00=>00 00 00 01=1 W

Socket Change Report

The device will report a socket status packet when the status changes.

Channel Type Byte Description
08 70 1

00: Close by Command, 10: Close by button

01: Open by Command, 11: Open by button

Example:
087011
Channel Type Value
08 70 11 => Open by button

Power Outage Alert

The device is equipped with capacitor for power outage alert. It will report an alert message when power supply is disconnected. This feature only works with hardware version 1.2 and later.
ff3fff
Channel Type Value
ff 3f ff: Reversed