It is necessary to connect the sensor to the EM500 transceiver to make the whole device work.
1. Take off the mounting bracket on the transceiver, remove the screws and the bottom
cover with the waterproof connector.


2. Pass all sensor wires through the waterproof connector and leave sufficient length for
connecting to the EM500 transceiver, then tighten the waterproof connector to the bottom
cover.


3. Screw the sensor wires to the terminal block of the EM500 transceiver tightly
referring to the label or Hardware Overview section. After wiring, gently pull the wires
to ensure they are securely fastened to the transceiver.


4. Restore everything to its due position. When restoring the bottom cover, ensure the
red arrow faces the front of the transceiver.


Note: The rubber seal
and rubber screw caps should be installed accordingly to prevent water from
entering.