General Setting

General settings include the basic parameters of the device.

Parameter Description
Reporting Interval The interval to report current data to network server. Range: 1-1080 minutes, Default: 10 minutes.
Pressure Unit
Change the pressure unit displayed on the ToolBox.
Note:
  1. The pressure unit in the reporting package is fixed as kPa.
  2. Please modify the threshold settings if the unit is changed.
Data Storage

Disable or enable to store periodic report data locally. The stored data can be exported as CSV format file and saved to smartphone via ToolBox.





Note:
  1. It is necessary to sync the time to ensure the data is stored in correct time.
  2. The device will still store the data even the network status is de-activated.
  3. ToolBox App can only export the last 14 days' data at most.
Data Retransmission Disable or enable data retransmssion. When the device detects the network status is de-activated via Rejoin Mode, the device will record a data lost time point and re-transmit the lost data after device re-connects to the network.
Note:
  1. This setting only takes effect when Data Storage is enabled.
  2. If the device is rebooted or re-power when data retransmission is not completed, the device will re-send all retransmission data again after device is reconnected to the network.

  3. If the network is disconnected again during data retransmission, it will only send the latest disconnected data.

  4. The default report data retransmission interval is 600s, this can be changed via downlink command.
  5. The reported format of retransmission data will include timestamps and is different from periodic report data.
  6. This setting will increase the uplink frequencies and shorten the battery life.
Change Password Change the device password for ToolBox App to write this device or ToolBox software to log in the device.