System

Device Info

All information about the hardware and software can be checked on this page.

User



Parameters Description


You can change the login password of this device.



Click to set three security questions for your device. In case that you forget the password, you can click Forget Password button on login page to reset the password by answering three security questions correctly.



Click to add a viewer, who will only have access to the "Dashboard" and "Report" interfaces.

Time Configuration



Parameters Description
Time Zone Choose the time zone for your location.
Daylight Saving Time Enable or disable Daylight Saving Time (DST).

Start Time: the start time of DST time range.

End Time:the end time of DST time range.

DST Bias: the DST time will be faster according to this bias setting.

Synchronize Mode Synchronize the time. Gateway Timing or Manual Timing is optional.
Gateway Timing: Synchronize the system time with embedded network server of Milesight gateway when LoRaWAN® version is 1.0.3.

Time Interval: Set the interval to sync time with gateway.

Manual Timing: Manual time synchronization.

Setting Time: Set the device time manually.

Synchronize with your computer time: Click to manually synchronize of computer time.

System Maintenance



Parameters

Description

Frequency Adjustment Adjust the ToF frequency modulation mode to avoid the interference of surrounding IR devices. Please avoid using the same mode if there are multiple VS135 devices around.
Note: if there is only one option, please contact Milesight IoT support: iot.support@milesight.com
ToF Lighting Mode Adjust the ToF light mode as Always On or Schedule. When using Schedule mode, the device will only turn on the ToF light during scheduled time range to save power.
Note:
  1. ToF light off will not affect the periodic report.
  2. During validation, the ToF lighting will be fixed as On irregardless of its lighting mode configuration.
  3. When using ToF Lighting Mode, the Dashboard will display relevant information.

ToF Noise Filtering Filter the noisy point on the screen when working with dark floor or carpet.
Noise Filtering Level Set the appropriate noise filtering level according to the actual image. The more difficult it is to see the target, the higher the filter value should be set.
Tilt Correction Enable to automatic compensation of person height values when the device is mounted at a tilt.
LED Indicator switch Enable or disable LED indicator when device is in normal operation.
Reset Recovery device basic configuration: keep the IP settings and user information when resetting.
Recovery device to factory settings: reset device to factory default, which needs to verify admin password.
Reboot Restart the device immediately.
Upgrade Click the folder icon and select the upgrading file, then click the Upgrade button to upgrade. The update will be done when the system reboots successfully.
Note: The upgrade process takes about 1-10 minutes. Do not turn off the power and complete automatic restart after the upgrade.
Backup and Restore Export Config File: Export configuration file.
Import Config File: Click the file icon and select the configuration file, click Import button to import configuration file.
Diagnostics System Log: Download log files that can be used for troubleshooting.
Log Mode - File: Select the desired level of the download log files for troubleshooting. Recommendation level to Fatal, Error and Warn.

Fatal: recording device crashes or unrecoverable critical events

Error: recording errors that is abnormal for a critical function

Warn: recording events that may cause problems

Debug: recording detailed internal operational and status information

Trace: recording all events