Preparation before Installation
Installation Position
- Avoid exposing the device to direct sunlight.
- Avoid placing the device near reflective surfaces such as glass, which may affect detection accuracy.
- Avoid exposing the master device to areas where an IR device is around (IR remote controller, etc.).
- The best installation height is 0.7~1.2m from the ground.
- The recommended detection range is 1.2~3m.
- Ensure that there are no obstructions between the master and node devices, and that they are aligned parallel to each other.
Installation Requirement
There are two ways to fix the devices: 3M Tape or Mounting Kits. Please check the precautions before selecting the appropriate installation method.
- Fixed by 3M Tape
-
Note: To ensure the devices are securely installed and prevent them from falling due to adhesive peeling, please strictly adhere to the following requirements:
- Install the device on a dry, smooth, sturdy, grease-free wall.
- Do not install the device on rough, damp, crumbling, greasy, or wallpapered walls.
- Before installation, wipe the wall with a clean cloth to ensure it is free of dust and grease.
- After adhering the device to the wall, press firmly to ensure it is fully adhered. Allow 24 hours for the best adhesion results.
- If the wall conditions do not meet the above requirements, choose an alternative installation method, such as screw fixation.
- Fixed by Mounting Kits
-
Note:
- Wall materials must have sufficient strength and stability to ensure that screws are securely fastened and the overall structure is sturdy.
- Screws should be fastened in locations that avoid electrical wiring, water pipes, and other elements within the wall to prevent damage to the wall structure or safety hazards.